1.
Sensors and Actuators B: Chemical ; : 134047, 2023.
Article in English | ScienceDirect | ID: covidwho-2328014

ABSTRACT

The rapid and accurate measurement of Raman signals on the test line (T-line) of surface-enhanced Raman scattering immunochromatography assay (SERS-ICA) strip is necessary for on-site detection based on SERS. Here, a novel linear spot Raman detector which can directly collect the SERS signals of the whole T-line on the dual-diagnostic SERS-ICA strip is developed for detection of multiple respiratory viruses via two magnetic SERS tags within 26min. The tags modified with two Raman reporter molecules can specifically recognize two viruses, thus enabling the simultaneous detection of both viruses on one T-line. Measured by the linear Raman detector, the limits of detection of the proposed dual-diagnostic SERS-ICA strip is as low as 870 and 263 copies/mL for severe acute respiratory syndrome coronavirus 2 and H1N1, respectively. The dual-diagnostic strip combined with the novel Raman detector herein are of great importance in the differential diagnosis of respiratory pathogens and show potential in the rapid and accurate diagnosis and control of emerging acute respiratory diseases.

2.
Front Microbiol ; 13: 1074513, 2022.
Article in English | MEDLINE | ID: covidwho-2311561

ABSTRACT

Porcine deltacoronavirus (PDCoV) cause diarrhea and dehydration in newborn piglets and has the potential for cross-species transmission. Rapid and early diagnosis is important for preventing and controlling infectious disease. In this study, two monoclonal antibodies (mAbs) were generated, which could specifically recognize recombinant PDCoV nucleocapsid (rPDCoV-N) protein. A colloidal gold immunochromatographic assay (GICA) strip using these mAbs was developed to detect PDCoV antigens within 15 min. Results showed that the detection limit of the GICA strip developed in this study was 103 TCID50/ml for the suspension of virus-infected cell culture and 0.125 µg/ml for rPDCoV-N protein, respectively. Besides, the GICA strip showed high specificity with no cross-reactivity with other porcine pathogenic viruses. Three hundred and twenty-five fecal samples were detected for PDCoV using the GICA strip and reverse transcription-quantitative real-time PCR (RT-qPCR). The coincidence rate of the GICA strip and RT-qPCR was 96.9%. The GICA strip had a diagnostic sensitivity of 88.9% and diagnostic specificity of 98.5%. The specific and efficient detection by the strip provides a convenient, rapid, easy to use and valuable diagnostic tool for PDCoV under laboratory and field conditions.

3.
J Clin Virol Plus ; 2(4): 100109, 2022 Nov.
Article in English | MEDLINE | ID: covidwho-2273286

ABSTRACT

The Omicron emerged in November 2021 and became the predominant SARS-CoV-2 variant globally. It spreads more rapidly than ancestral lineages and its rapid detection is critical for the prevention of disease outbreaks. Antigen tests such as immunochromatographic assay (ICA) and chemiluminescent enzyme immunoassay (CLEIA) yield results more quickly than standard polymerase chain reaction (PCR). However, their utility for the detection of the Omicron variant remains unclear. We herein evaluated the performance of ICA and CLEIA in saliva from 51 patients with Omicron and 60 PCR negative individuals. The sensitivity and specificity of CLEIA were 98.0% (95%CI: 89.6-100.0%) and 100.0% (95%CI: 94.0-100.0%), respectively, with fine correlation with cycle threshold (Ct) values. The sensitivity and specificity of ICA were 58.8% (95%CI: 44.2-72.4%) and 100.0% (95%CI: 94.0-100.0%), respectively. The sensitivity of ICA was 100.0% (95%CI: 80.5-100.0%) when PCR Ct was less than 25. The Omicron can be efficiently detected in saliva by CLEIA. ICA also detects high viral load Omicron using saliva.

4.
Pathogens ; 11(11)2022 Oct 28.
Article in English | MEDLINE | ID: covidwho-2090299

ABSTRACT

This study established a portable and ultrasensitive detection method based on recombinase polymerase amplification (RPA) combined with high-sensitivity multilayer quantum dot (MQD)-based immunochromatographic assay (ICA) to detect the severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). The RPA-MQD-based ICA method is reported for the first time and has the following advantages: (i) RPA is free from the constraints of instruments and can be promoted in point-of-care testing (POCT) scenarios, (ii) fluorescence ICA enhances the portability of detection operation so that the entire operation time is controlled within 1 h, and (iii) compared with common colorimetric-based RPA-ICA, the proposed assay used MQD to provide strong and quantifiable fluorescence signal, thus enhancing the detection sensitivity. With this strategy, the proposed RPA-MQD-based ICA can amplify and detect the SARS-CoV-2 nucleic acid on-site with a sensitivity of 2 copies/reaction, which is comparable to the sensitivity of commercial reverse transcription quantitative polymerase chain reaction (RT-qPCR) kits. Moreover, the designed primers did not cross-react with other common respiratory viruses, including adenovirus, influenza virus A, and influenza virus B, suggesting high specificity. Thus, the established portable method can sensitively detect SARS-CoV-2 nucleic acid without relying on equipment, having good application prospects in SARS-CoV-2 detection scenarios under non-lab conditions.

5.
Diagnostics (Basel) ; 12(10)2022 Oct 07.
Article in English | MEDLINE | ID: covidwho-2065755

ABSTRACT

This study evaluated the performances of immunoassays (LFIA and ELISA) designed for SARS-CoV-2 Antigen (Ag)-detection in nasopharyngeal (NP) and serum samples in comparison to RT-PCR. NP samples from patients with respiratory symptoms (183 RT-PCR-positive and 74 RT-PCR-negative samples) were collected from March to April and November to December 2020. Seroconversion and antigen dynamics were assessed by symptom onset and day of RT-PCR diagnosis. Serum samples from 87 COVID-19 patients were used to investigate the added value of Ag quantification, at diagnosis and during follow-up. The sensitivity of COVID-VIRO-LFIA on samples with Ct ≤ 33, considered as the contagious threshold, was 86% on NPs (CI 95%: 79-90.5) and 76% on serum samples (CI 95%: 59.4-88), with a specificity of 100%. Serum N-Ag was detected during active infection as early as day two from symptom onset, with a diagnostic sensitivity of 81.5%. Within one week of symptom onset, diagnostic sensitivity and specificity reached 90.9% (95% CI, 85.1%-94.6%) and 98.3% (95% CI, 91.1%-99.9%), respectively. Serum N-Ag concentration closely correlated with disease severity. Longitudinal analysis revealed the simultaneous increase of antibodies and decrease of N-Ag. Sensitivities of COVID-VIRO-LFIA and COV-QUANTO-ELISA tests on NP and serum samples were close to 80%. They are suitable COVID-19-laboratory diagnostic tests, particularly when blood samples are available, thus reducing the requirement for NP sampling, and subsequent PCR analysis. ELISA titers may help to identify patients at risk of poor outcomes.

6.
Pharmaceutical Journal ; 306(7947), 2022.
Article in English | EMBASE | ID: covidwho-2064938
7.
Kafkas Universitesi Veteriner Fakultesi Dergisi ; 28(4):507-514, 2022.
Article in English | EMBASE | ID: covidwho-2006516

ABSTRACT

In this study, it was aimed to evaluate the relationship between the clinical course of the disease and hematological data, serum 25-hydroxyvitamin D (25 (OH) D), iron (Fe), free iron-binding capacity (UIBC), and D-dimer levels in calves with diarrhea in the neonatal period. Within the scope of the study, 10 healthy calves (group-I) and 30 diarrheal calves in the neonatal period of different races, ages and genders were used. Calves with diarrhea were divided into mild (group-II, n=10), moderate (group-III, n=10) and severe (group-IV, n=10) groups. Blood samples were taken from calves in all groups at once. Hematological analyzes were performed using a veterinary-specific hematology analyzer device. In serum samples, 25 (OH) D3, Fe and UIBC levels were determined with an autoanalyzer, and D-dimer levels were determined with an automatic immunoassay analyzer. In the hematological analysis, an increase was observed in the number of LYMs (lymphocytes) in group-II (5.04±1.3) and III (5.2±3.3) compared to group-I (4.47±1.2), and a decrease was observed in group IV (2.76±0.9) (P<0.05). Fe levels in group-II (59±56), group III (56±52) and group IV (72±63) were found to be decreased compared to group-I (131±66) (P<0.05). It was determined that the 25 (OH) D3 level of group IV (13.4±8.5) was higher than that of group-I (6.12±2.73) (P<0.05). D-dimer levels of group-III (1.15±1.13) and group-IV (0.96±0.88) were found to be higher than group-I (0.10±1.46) (P<0.05).

8.
Biosensors (Basel) ; 12(7)2022 Jun 22.
Article in English | MEDLINE | ID: covidwho-1911186

ABSTRACT

The pandemic of new coronary pneumonia caused by the COVID-19 virus continues to ravage the world. Large-scale population testing is the key to controlling infection and related mortality worldwide. Lateral flow immunochromatographic assay (LFIA) is fast, inexpensive, simple to operate, and easy to carry, very suitable for detection sites. This study developed a COVID-19 N protein detect strip based on p-toluenesulfonyl modified rare earth fluorescent microspheres. The p-toluenesulfonyl-activated nanomaterials provide reactive sulfonyl esters to covalently attach antibodies or other ligands containing primary amino or sulfhydryl groups to the nanomaterial surface. Antibodies are immobilized on these nanomaterials through the Fc region, which ensures optimal orientation of the antibody, thereby increasing the capture rate of the target analyte. The use of buffers with high ionic strength can promote hydrophobic binding; in addition, higher pH could promote the reactivity of the tosyl group. The detection limit of the prepared COVID-19 N protein strips can reach 0.01 ng/mL, so it has great application potential in large-scale population screening.


Subject(s)
COVID-19 , SARS-CoV-2 , Antibodies , COVID-19/diagnosis , Humans , Immunoassay/methods , Limit of Detection , Microspheres
9.
Lett Appl Microbiol ; 74(6): 1001-1007, 2022 Jun.
Article in English | MEDLINE | ID: covidwho-1891648

ABSTRACT

African swine fever (ASF), a highly contagious and lethal disease, poses a tremendous threat and burden to the swine industry worldwide. Lack of available vaccines or treatments leaves rapid diagnosis as the key tool to control the disease. Quantum dots (QDs) are unique fluorescent semiconductor nanoparticles, highly versatile for biological applications. In this study, we developed a quantum dots-based fluorescent immunochromatographic assay (QDs-FICA) using CD2v as the diagnosis antigen to detect ASFV antibodies. The titre of the test strip was 1 : 5·12 × 105 . In addition, the strip was highly specific to anti-ASFV serum and had no cross-reaction with CSFV, PPV, PRRSV, PCV-2, PRV and FMDV. Moreover, a comparative test of 71 clinical samples showed that the coincidence rate was 85·92% between the test strip and the commercial ELISA kit (coated with p30, p62 and p72). The QDs-FICA can be used to detect ASFV antibodies, which is meaningful for the surveillance, control and purification of ASF.


Subject(s)
African Swine Fever Virus , African Swine Fever , Quantum Dots , African Swine Fever/diagnosis , African Swine Fever/prevention & control , Animals , Diagnosis, Differential , Immunoassay , Swine
10.
Klin Lab Diagn ; 67(4): 227-233, 2022 Apr 17.
Article in English | MEDLINE | ID: covidwho-1876637

ABSTRACT

The paper present the results of a survey of people who have undergone immunization with a combined vector vaccine for the prevention of coronavirus infection COVID-19 «Sputnik V - Gam-COVID-Vac¼, as well as COVID-19 recovalents. Using a quantitative enzyme-linked immunosorbent assay, the levels of specific IgG were determined in persons who had had different degrees of severity before vaccination, in persons who were immuno-negative before immunization, as well as in convalescents who had undergone coronavirus infection of varying severity. The immunological targeting of antibodies against various SARS-CoV-2 proteins is considered.


Subject(s)
COVID-19 , Antibodies, Viral , COVID-19/prevention & control , COVID-19 Vaccines , Humans , Immunization , SARS-CoV-2 , Vaccination
11.
Nano LIFE ; 12(1), 2022.
Article in English | EMBASE | ID: covidwho-1854417

ABSTRACT

Nanomedicine or nanotechnology exhibits outstanding features to challenge severe health issues including pathogenic viral infections, the most culpable invaders in the present situation. The perpetual mutational pattern in viruses topped with raising resistance to drug epitomizes the current situation as a trigger to explore nanotech platforms in antiviral therapies. Referring to novel physicochemical features of nanomaterials associated with effective drug delivery, it is viewed as an ideal strategy for treatment of viral infections. The coronavirus induced pathogenesis, including MERS, SARS and SARS-CoV-2 infections, has triggered alarming and highly dangerous precedents against existence of humans. Applications of nanotechnology can serve a new direction for disinfection or treatment of viruses. Presently, various types of nanomaterials, such as nanogels, nanospheres, nanocapsules, liposomes, nanoparticles and many others, that have been investigated in vivo and in vitro for successful drug delivery, vaccination, diagnostic assay and device development with anticipation to be translated in advanced clinical practices, need a collective relook. This paper intents to contribute insightful critique of current studies on the efficacy of nanoplatforms as drug transporter, diagnostic tool and vaccine candidate against pathogenic viruses counting the highly pathogenic and incurable "coronaviruses".

12.
SAGE Open Med ; 10: 20503121221088090, 2022.
Article in English | MEDLINE | ID: covidwho-1759667

ABSTRACT

Objectives: The severe acute respiratory syndrome coronavirus 2 causes coronavirus disease 2019. A serological test is conducted to determine prior infection by severe acute respiratory syndrome coronavirus 2. We investigated whether the results of anti-severe acute respiratory syndrome coronavirus 2 antibody tests are modified in patients with rheumatoid arthritis. Methods: Patients in Japan with rheumatoid arthritis were recruited at Sagamihara Hospital from July 2014 to October 2015 (n = 38; 2014 cohort) and at Tokyo Hospital from June to October 2020 (n = 93; 2020 cohort). Anti-severe acute respiratory syndrome coronavirus 2 antibodies were measured by electrochemiluminescence immunoassay or immunochromatographic assay. Results: Anti-severe acute respiratory syndrome coronavirus 2 antibodies were not detected in any of the samples from rheumatoid arthritis patients tested by electrochemiluminescence immunoassay. Anti-severe acute respiratory syndrome coronavirus 2 antibodies were detected by immunochromatographic assay in the 3 (7.9%) serum samples in the 2014 cohort and 15 (16.1%) serum samples in the 2020 cohort. The IgM rheumatoid factor levels were increased in rheumatoid arthritis patients with IgM anti-severe acute respiratory syndrome coronavirus 2 antibodies detected by immunochromatographic assay (mean ± standard deviation (IU/ml), 1223.0 ± 1308.7 versus 503.6 ± 1947.2; P = 0.0101). The levels of IgG rheumatoid factor were also upregulated in rheumatoid arthritis patients with IgM anti-severe acute respiratory syndrome coronavirus 2 antibodies detected by immunochromatographic assay (4.0 ± 0.7 versus 2.4 ± 0.9; P = 0.0013). Conclusion: The results of IgM anti-severe acute respiratory syndrome coronavirus 2 antibody testing by immunochromatographic assay are modified by IgM or IgG rheumatoid factors in rheumatoid arthritis patients.

13.
Med Princ Pract ; 30(4): 385-394, 2021.
Article in English | MEDLINE | ID: covidwho-1354613

ABSTRACT

OBJECTIVE: To assess the diagnostic performance of lateral flow immunochromatographic assays (LFAs) of 4 different manufacturers to identify SARS-CoV-2 antibodies (IgM, IgG, or total), comparing them with the nucleic acid amplification test (NAAT) or the clinical defined test (definite or probable SARS-CoV-2 infection, respectively). METHODS: One hundred nineteen serum samples were randomly selected by convenience and distributed in the following groups: (1) group with SARS-CoV-2 infection (n = 82; RT-qPCR positive [definite, n = 70] and probable [n = 12]); (2) other diseases (n = 27; other viruses identified [n = 8] and SARS of other etiologies [n = 19]); and (3) healthy control group (n = 10). LFAs of 4 manufacturers were compared: MedTest Coronavirus (COVID-19) IgG/IgM (MedLevensohn, Brazil); COVID-19 IgG/IgM ECO Test (Ecodiagnóstica, Brazil); Camtech COVID-19 IgM/IgG Rapid Test Kit (Camtech Diagnostics Pte Ltd, Singapore); and 1-Step COVID-19 Test for total antibodies (Guangzhou Wondfo Biotech Co., China). RESULTS: The 4 tests studied showed high diagnostic performance characteristics for the diagnoses of definite or probable SARS-CoV-2 infection. The best measures were for the Wondfo test: sensitivity (86.59%; 95% CI: 77.26-93.11%), specificity (100%; 90.51-100%), DOR (257; 60-1,008), LR+ (33.43; 4.82-231.85), LR- (0.13; 0.08-0.23), accuracy (90.76%; 84.06-95.29%), and Matthews correlation coefficient (MCC) 0.82. Although considering only the probable SARS-CoV-2 infection (PCR-) cases, all the kits studied showed limited values. CONCLUSION: Our data demonstrate the excellent performance of LFA for the diagnoses of definite or probable SARS-CoV-2 infection. There was substantial heterogeneity in sensitivities of IgM and IgG antibodies among the different kits. LFA tests cannot replace molecular diagnostics but should be used as an additional screening tool.


Subject(s)
Antibodies, Viral/blood , COVID-19 Testing/methods , Serologic Tests/methods , Brazil/epidemiology , Case-Control Studies , Female , Humans , Immunoassay/methods , Immunoglobulin G/blood , Immunoglobulin M/blood , Male , Nucleic Acid Amplification Techniques , Pandemics , SARS-CoV-2 , Sensitivity and Specificity
14.
Sens Actuators B Chem ; 345: 130372, 2021 Oct 15.
Article in English | MEDLINE | ID: covidwho-1294238

ABSTRACT

Rapid and accurate diagnosis of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) and influenza A virus (FluA) antigens in the early stages of virus infection is the key to control the epidemic spread. Here, we developed a two-channel fluorescent immunochromatographic assay (ICA) for ultrasensitive and simultaneous qualification of the two viruses in biological samples. A high-performance quantum dot nanobead (QB) was fabricated by adsorption of multilayers of dense quantum dots (QDs) onto the SiO2 surface and used as the highly luminescent label of the ICA system to ensure the high-sensitivity and stability of the assay. The combination of monodispersed SiO2 core (∼180 nm) and numerous carboxylated QDs formed a hierarchical shell, which ensured that the QBs possessed excellent stability, superior fluorescence signal, and convenient surface functionalization. The developed ICA biosensor achieved simultaneous detection of SARS-CoV-2 and FluA in one test within 15 min, with detection limits reaching 5 pg/mL for SARS-CoV-2 antigen and 50 pfu/mL for FluA H1N1. Moreover, our method showed high accuracy and specificity in throat swab samples with two orders of magnitude improvement in sensitivity compared with traditional AuNP-based ICA method. Hence, the proposed method is a promising and convenient tool for detection of respiratory viruses.

15.
Int J Infect Dis ; 108: 483-486, 2021 Jul.
Article in English | MEDLINE | ID: covidwho-1253015

ABSTRACT

INTRODUCTION: A large number of COVID-19 patients are in recovery, and millions of people are vaccinated for COVID-19 globally. This calls for a rapid screening strategy of SARS-CoV-2 protective antibodies, generated in rehabilitated and vaccinated populations. METHODS: Serum samples collected over a follow-up period of six months from 306 COVID-19 cases discharged from Wuhan Tongji Hospital were analyzed. Anti-S Abs were detected by colloidal gold immunochromatographic assay (GICA), and neutralizing antibodies (nAbs) were detected by chemiluminescent microparticle immunoassay (CMIA). RESULTS: Most COVID-19 survivors tested positive for anti-S Abs (83.7%) and nAbs (98.0%) 6 months after being discharged from the hospital, and the levels of anti-S Abs in the blood were highly positively correlated with nAbs (r = 0.652, P < 0.0001). The positivity rate of nAbs for patients with anti-S Abs positive was 100%. CONCLUSIONS: There is a good agreement between anti-S Abs detected by GICA and nAbs detected by CMIA. It indicates that anti-S Abs detected by GICA may be used as a cheaper screening strategy for detectable SARS-CoV-2 nAbs in COVID-19 convalescent individuals.


Subject(s)
Antibodies, Neutralizing , COVID-19 , Antibodies, Viral , Gold Colloid , Humans , Immunoassay , SARS-CoV-2
16.
Microchem J ; 167: 106305, 2021 Aug.
Article in English | MEDLINE | ID: covidwho-1198979

ABSTRACT

Since December 2019, we have been in the battlefield with a new threat to the humanity known as severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). In this review, we describe the four main methods used for diagnosis, screening and/or surveillance of SARS-CoV-2: Real-time reverse transcription polymerase chain reaction (RT-PCR); chest computed tomography (CT); and different complementary alternatives developed in order to obtain rapid results, antigen and antibody detection. All of them compare the highlighting advantages and disadvantages from an analytical point of view. The gold standard method in terms of sensitivity and specificity is the RT-PCR. The different modifications propose to make it more rapid and applicable at point of care (POC) are also presented and discussed. CT images are limited to central hospitals. However, being combined with RT-PCR is the most robust and accurate way to confirm COVID-19 infection. Antibody tests, although unable to provide reliable results on the status of the infection, are suitable for carrying out maximum screening of the population in order to know the immune capacity. More recently, antigen tests, less sensitive than RT-PCR, have been authorized to determine in a quicker way whether the patient is infected at the time of analysis and without the need of specific instruments.

17.
Front Med (Lausanne) ; 8: 616106, 2021.
Article in English | MEDLINE | ID: covidwho-1145566

ABSTRACT

Novel severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) is the etiologic agent of the ongoing coronavirus disease 2019 (COVID-19) pandemic, which has reached 28 million cases worldwide in 1 year. The serological detection of antibodies against the virus will play a pivotal role in complementing molecular tests to improve diagnostic accuracy, contact tracing, vaccine efficacy testing, and seroprevalence surveillance. Here, we aimed first to evaluate a lateral flow assay's ability to identify specific IgM and IgG antibodies against SARS-CoV-2 and second, to report the seroprevalence estimates of these antibodies among health care workers and healthy volunteer blood donors in Panama. We recruited study participants between April 30th and July 7th, 2020. For the test validation and performance evaluation, we analyzed serum samples from participants with clinical symptoms and confirmed positive RT-PCR for SARS-CoV-2, and a set of pre-pandemic serum samples. We used two by two table analysis to determine the test positive and negative percentage agreement as well as the Kappa agreement value with a 95% confidence interval. Then, we used the lateral flow assay to determine seroprevalence among serum samples from COVID-19 patients, potentially exposed health care workers, and healthy volunteer donors. Our results show this assay reached a positive percent agreement of 97.2% (95% CI 84.2-100.0%) for detecting both IgM and IgG. The assay showed a Kappa of 0.898 (95%CI 0.811-0.985) and 0.918 (95% CI 0.839-0.997) for IgM and IgG, respectively. The evaluation of serum samples from hospitalized COVID-19 patients indicates a correlation between test sensitivity and the number of days since symptom onset; the highest positive percent agreement [87% (95% CI 67.0-96.3%)] was observed at ≥15 days post-symptom onset (PSO). We found an overall antibody seroprevalence of 11.6% (95% CI 8.5-15.8%) among both health care workers and healthy blood donors. Our findings suggest this lateral flow assay could contribute significantly to implementing seroprevalence testing in locations with active community transmission of SARS-CoV-2.

18.
Int J Nanomedicine ; 16: 715-724, 2021.
Article in English | MEDLINE | ID: covidwho-1067512

ABSTRACT

OBJECTIVE: The coronavirus disease (COVID-19) pandemic, caused by severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), is now rapidly spreading globally. Serological tests are an important method to assist in the diagnosis of COVID-19, used for epidemiological investigations. In this study, we aimed to investigate the impact of different types of vacuum collection tubes on the detection of SARS-CoV-2 IgM and IgG antibodies, using the colloidal gold immunochromatographic assay (GICA). PATIENTS AND METHODS: A total of 112 patients with COVID-19 and 200 healthy control subjects with no infection were enrolled in this study. Their serum and plasma were collected into four different types of vacuum blood collection tubes. SARS-CoV-2 IgM and IgG specific antibodies in the plasma and serum were then detected by GICA and chemiluminescence assay (CA), respectively. In addition, the particle sizes of different colloidal gold solutions in the presence of different anticoagulants and coagulants were evaluated by both laser diffraction (Malvern) and confocal laser microscope, respectively. RESULTS: Our results revealed that anticoagulated plasma with EDTA-K2 improved the positive detection rate of SARS-CoV-2 IgM antibodies. Furthermore, our results shown that the detection results by GICA and CA were highly consistent, especially, the results of EDTA-K2 anticoagulated plasma detected by GICA was more consistent with CA results. We confirmed that EDTA-K2 could improve the detection sensitivity of SARS-CoV-2 IgG antibodies by chelating excessive colloidal gold compared with sodium citrate or lithium heparin, these methodologies did not appear to cause false positives. Colloidal gold particles could be chelated and aggregated by EDTA-K2, but not by sodium citrate, lithium heparin and coagulants. CONCLUSION: GICA is widely used to detect antibodies for the advantages of convenient, fast, low cost, suitable for screening large sample and require minimal equipment. In this study, we found that EDTA-K2 amplified the positive antibody signal by chelating colloidal gold and improved the detection sensitivity of SARS-CoV-2 IgM and IgG antibodies when using the GICA. Therefore, we suggested that EDTA-K2 anticoagulated plasma was more suitable for the detection of SARS-CoV-2 antibodies.


Subject(s)
Antibodies, Viral/isolation & purification , Chelating Agents/chemistry , Edetic Acid/chemistry , Gold Colloid/chemistry , Immunoassay/methods , Immunoglobulin G/isolation & purification , Immunoglobulin M/isolation & purification , SARS-CoV-2/immunology , Adult , Antibodies, Viral/blood , Antibody Specificity/immunology , COVID-19/blood , COVID-19/immunology , COVID-19/virology , Female , Humans , Immunoglobulin G/blood , Immunoglobulin M/blood , Male , Middle Aged , Molecular Weight , Particle Size , Polymers/chemistry , Sensitivity and Specificity
19.
J Clin Microbiol ; 59(2)2021 01 21.
Article in English | MEDLINE | ID: covidwho-1066814

ABSTRACT

This study assessed the diagnostic performance of the new COVID19SEROSpeed IgM/IgG rapid test (BioSpeedia, a spinoff of the Pasteur Institute of Paris) for the detection of antibodies against severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) in comparison to other commercial antibody assays through a large cross-European investigation. The clinical specificity was assessed on 215 prepandemic sera (including some from patients with viral infections or autoimmune disorders). The clinical sensitivity was evaluated on 710 sera from 564 patients whose SARS-CoV-2 infection was confirmed by quantitative reverse transcription-PCR (qRT-PCR) and whose antibody response was compared to that measured by five other commercial tests. The kinetics of the antibody response were also analyzed in seven symptomatic patients. The specificity of the test (BioS) on prepandemic specimens was 98.1% (95% confidence interval [CI], 96.2% to 99.4%). When tested on the 710 pandemic specimens, BioS showed an overall clinical sensitivity of 86.0% (95% CI, 0.83 to 0.89), with good concordance with the Euroimmun assay (overall concordance of 0.91; Cohen's kappa coefficient of 0.62). Due in part to simultaneous detection of IgM and IgG for both S1 and N proteins, BioS exhibited the highest positive percent agreement at ≥11 days post-symptom onset (PSO). In conclusion, the BioS IgM/IgG rapid test was highly specific and demonstrated a higher positive percentage of agreement than all the enzyme-linked immunosorbent assay/chemiluminescence immunoassay (ELISA/CLIA) commercial tests considered in this study. Moreover, by detecting the presence of antibodies prior to 11 days PSO in 78.2% of the patients, the BioS test increased the efficiency of the diagnosis of SARS-CoV-2 infection in the early stages of the disease.


Subject(s)
COVID-19 Serological Testing/methods , COVID-19/diagnosis , Immunoassay/methods , SARS-CoV-2/isolation & purification , Antibodies, Viral/blood , Antigens, Viral/immunology , COVID-19/blood , COVID-19/pathology , Chromatography, Affinity , Europe , Humans , Immunoglobulin G/blood , Immunoglobulin M/blood , Kinetics , SARS-CoV-2/immunology , Sensitivity and Specificity , Time Factors
20.
Clin Microbiol Infect ; 27(2): 289.e1-289.e4, 2021 Feb.
Article in English | MEDLINE | ID: covidwho-813533

ABSTRACT

OBJECTIVES: Rapid, reliable and easy-to-implement diagnostics that can be adapted in early severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) diagnosis are critical to combat the epidemic. SARS-CoV-2 nucleocapsid protein (NP) is an ideal target for viral antigen-based detection. A rapid and convenient method was developed based on fluorescence immunochromatographic (FIC) assay to detect the SARS-CoV-2 NP antigen. However, the accuracy of this diagnostic method needs to be examined. METHODS: This prospective study was carried out between 10 and 15 February 2020 in seven hospitals in Wuhan and one hospital in Chongqing, China. Participants with clinically suspected SARS-CoV-2 infection were enrolled. NP antigen testing by FIC assay and nucleic acid (NA) testing by real-time reverse transcriptase PCR (RT-PCR) were performed simultaneously in a blinded manner with the same nasopharyngeal swab sample. The diagnostic accuracy of NP antigen testing was calculated by taking NA testing of RT-PCR as the reference standard, in which samples with a cycle threshold (Ct) value of ≤40 were interpreted as positive for SARS-CoV-2. RESULTS: A total of 253 participants were enrolled; two participants were excluded from the analyses because of invalid NP testing results. Of 251 participants (99.2%) included in the diagnostic accuracy analysis, 201 (80.1%) had a Ct value of ≤40. With Ct value 40 as the cutoff of NA testing, the sensitivity, specificity and percentage agreement of the FIC assay was 75.6% (95% confidence interval, 69.0-81.3), 100% (95% confidence interval, 91.1-100) and 80.5% (95% confidence interval, 75.1-84.9) respectively. CONCLUSIONS: With RT-PCR assay as the reference standard, NP antigen testing by FIC assay shows high specificity and relatively high sensitivity in SARS-CoV-2 diagnosis in the early phase of infection.


Subject(s)
Antigens, Viral/analysis , COVID-19 Testing/methods , COVID-19/diagnosis , Coronavirus Nucleocapsid Proteins/analysis , SARS-CoV-2/isolation & purification , Adolescent , Adult , Aged , COVID-19 Testing/standards , Female , Humans , Immunoassay , Male , Middle Aged , Nasopharynx/virology , Phosphoproteins/analysis , Prospective Studies , RNA, Viral/genetics , SARS-CoV-2/genetics , SARS-CoV-2/immunology , Sensitivity and Specificity , Young Adult